Generac designs and manufactures a complete line of
automatic transfer switches to meet the requirements of virtually any
emergency standby application.
RTS Transfer Switch
RTS transfer switches are designed to
operate with our R-Series Digital Controllers. Available in
both single and three-phase versions, these proven, open transition transfer
switches are ideal for residential, commercial and light industrial
applications. Both standard RTS and service entrance rated transfer switches
feature NEMA 3R enclosures for indoor or outdoor use. All standard RTS and
distributed load center transfer switches are UL and CUL Listed. NEMA 1
rated. Spec
Sheet
Distributed Load Center Switch
This 100 amp transfer switch has a
pre-wired, integrated load center for simple installation when only selected
emergency circuits will be served by the generator. Pre-wired flexible
internal conduit and seal tight external conduit provide simple connections
all the way from the generator to the 8, 10, 12, 14 or 16 circuit transfer
switch. Spec
Sheet
Service Entrance Rated Switch
Our service entrance rated models
include an integrated main breaker that eliminates the need for a separate
service disconnect when backing up all of the electrical loads in a
building. The switches are UL 1008 listed with a UL rated circuit breaker on
the utility side of the transfer contactor for full downstream
protection. Spec
Sheet
CSA Certified Service
Entrance Rated Switches
Generac is proud to offer the first
ever, CSA approved service rated transfer switches for Canadian use. These
switches use patent pending technology to allow for use in whole house
applications in Canada. The switches are available in 100 and 200 amp
ratings for single phase applications. The switches employ CUL rated circuit
breakers on the utility side of the transfer contactor for full downstream
protection. The aluminum enclosure is rated for NEMA/UL Type 3R installation
and is fully protected from the elements. Spec
Sheet
PowerManager® LTS
The PowerManager LTS is designed to
allow the most efficient use of the generator by monitoring and managing the
backed up essential and non-essential circuits. If the generator approaches
overload condition, the non-essential circuits are cycled off, allowing
essential circuits to remain powered. It features a built-in, 16-circuit
priority load center, a main contactor that protects the essential circuits
and a secondary contactor that protects non-essential circuits. The service
entrance-rated, NEMA 3R outdoor/indoor-rated enclosure has a side-opening
hinged cover and conforms to 2008 National Electrical Code sizing
standards. Spec
Sheet
GenReadyTM
Load Center
The GenReady load center is a hybrid
panel that operates as a normal load center and also allows for seamless
integration of standby generators. It is available in a NEMA 1 configuration
for indoor installations, or in a NEMA 3R configuration for outdoor
applications. Spec
Sheet